MP101403 latches in
presence of south pole and
unlatches in presence of north pole magnet
Excellent for
flow sensing and door interlock applications
Electrical
SPECIFICATIONS
Part
Number
Operating
Voltage Range (VDC)
Supply
Current (mA Max.)
Output
Output
Saturation Voltage (mV Max.)
Output
Current (mA Max.)
Operate
Temp Range
(°C)
Function
Operate
Point, gauss
(typical)
Release
Point, gauss
(typical)
MP101401
4.5 to 24
5.2
3-wire sink
400
20
-40 to +85
Unipolar
switch
210 (south)
190 (south)
MP101402
4.5 to 24
5.2
3-wire sink
400
20
-40 to +85
Unipolar
switch
65 (south)
45 (south)
MP101403
4.5 to 24
5.2
3-wire sink
400
20
-40 to +85
Bipolar switch
100 (south)
-100 (north)
These sensors require the use of an
external pull-up resistor, the value of which is dependent
on the supply voltage.
Pull-up resistor should be connected between output
(green) and Vcc (red). Click
here for additional advice about output terminology